Work out the fall, slope or run length of a drain pipe, see the slope as %, 1:N, in/ft or mm/m, and check it against the IPC minimum for its size.
A drain that is too flat silts up, and one laid backwards floods the room it was meant to empty. The fall is decided before the first length of pipe goes in. Give this calculator any two of the run length, the fall and the slope, and it works out the third. The slope comes back in every form a plan or a plumber might use: percent, 1 in N, inches per foot, millimetres per metre and degrees.
Add the pipe diameter and two more answers appear. One says whether the slope meets the minimum in the International Plumbing Code for that size. The other estimates how fast the water moves when the pipe runs full, so you can see whether it will carry solids away.
The calculator opens solving for the fall on a 30 ft run of 3 in PVC laid at 0.25 in per ft. It reports:
Load Sample moves on to 12 m of 110 mm pipe falling 150 mm (1 : 80), a 1 : 40 fall that needs a 12 m run to lose 300 mm, and 50 ft of 4 in cast iron falling only 4 in. That last one comes out at 0.08 in per ft and fails the code check.
Slope is fall divided by run, with both in the same unit. The other two answers are the same equation turned around. Switch Solve for and the current answer is written into its box, so nothing has to be retyped. Changing the slope format re-expresses the same slope rather than reading your number in the new format, and switching between metric and imperial converts every value. A 1 : N slope needs N above 1, or the tool says: “A 1 : N slope needs N greater than 1. For a quarter inch per foot, N is 48.”
The flow estimate uses Manning’s equation for a full pipe, V = (1/n) × R^⅔ × S^½. Here R is a quarter of the diameter and n is the pipe’s roughness: 0.010 for plastic and 0.013 for cast iron, clay or concrete.
The minimum slopes come from IPC table 704.1: ¼ in per ft up to 2½ in, ⅛ in per ft from 3 to 6 in, and 1/16 in per ft from 8 in. Other codes differ. In the UK, Approved Document H allows 1 : 80 for a 100 mm drain serving a WC, so check the one that applies to you. A drain is designed to run partly full, so the full-pipe velocity is a ceiling, not the speed it will run at. When even that ceiling is under the usual 2 ft/s (0.6 m/s) self-cleansing speed, the tool warns you to add fall.
Fall
7.5 in
2.083% · 1 : 48 · 0.25 in/ft · 1.193°
Inches per foot
0.25 in/ft
Percent
2.083%
Ratio
1 : 48
Angle
1.193°
IPC table 704.1 asks for at least ⅛ in per ft (1.04%) on a 3 in pipe. This run meets it.
Velocity running full
3.38 ft/s
Capacity running full
74.42 gal/min
Slope = fall ÷ run. Velocity from Manning’s equation for a full pipe, V = (1/n) R^⅔ S^½ with R = D/4; a drain normally runs part full, so treat it as an upper bound.